At 19:27:26 PST a PT132_MOD2 glitch caused a single-sensor VACSTAT glitch. The new code requires two chambers to glitch before alarming the VAC team, so in this case no cell phone alarms were sent.
The glitch lasted 4 seconds, and as before it was DeltaP which tripped, exceeded its trip level of 1.0e-08Torr (see attached).
I restarted vacstat_ioc.service on cdsioc0 to reset the system.