Displaying report 1-1 of 1.
Reports until 15:38, Wednesday 13 November 2024
H1 ISC
camilla.compton@LIGO.ORG - posted 15:38, Wednesday 13 November 2024 - last comment - 13:35, Monday 18 November 2024(81250)
IMC TRANS power changes up to 1% once we get to NLN and are thermalizing

While looking at locklosses today, Vicky and I noticed that after we reach NLN, the MC2/IM4 TRANS power increases 0.1 to 0.5%.  

Daniel helped look at this and we expect the ISS to change to keep the power out of the IMC constant, but the power after the IMC on IM4 TRANS (not centered) changes ~1% too. Everything downstream of the ISS AOM sees this change plot, something is seeing a slow ~1hour thermalization.

The same signals at LLO are show a similar amount of noise (slightly more in the MC2_TRANS) but no thermalization drift, but LLO has a lot less IFO thermalization.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 13:35, Monday 18 November 2024 (81337)

Elenna and Craig noted this in 68370 too. 

Displaying report 1-1 of 1.