Reports until 14:02, Wednesday 16 October 2013
H1 AOS
jason.oberling@LIGO.ORG - posted 14:02, Wednesday 16 October 2013 (8126)
BSC9 ETMx Alignment
IAS: J. Oberling
SUS: B. Bland, T. Sadecki
 
Betsy and Travis freed up the suspension this morning (no apparent rubbing, TFs will be run to confirm) and I took accurate pitch/yaw measurments, with our goal being to rough set the pitch after the cartridge install:

With the pitch only off by ~300 µrad after simply releasing the optic, no rough alignment is needed.  Now I need to correct the position errors from alog 8116 (no change with the suspension being free) along with the above yaw with the SEI crew.  Once this is done and SEI can finish final ISI payload and balancing we will fine align the ETMx pitch.