H1 Lockloss at 2100utc (9pm PT) After 5hr Lock.....Now What....Leaning To IMC-only Overnight.....

The plan for tonight's shift was to see how locking would go for H1.  Well....TJ handed over a locked H1, and then it stayed locked for 5hrs of the 6hr Eve shift!  

Vicky mentioned that the Lockloss at 0459utc looked like possible FSS glitch, but it looked "different".  She is going to post her plot about that.

Comments related to this report
victoriaa.xu@LIGO.ORG - 22:02, Wednesday 13 November 2024 (81274)

This lockloss (1415595557, 2024-11-13 20:58:59 PT) looks related to IMC (/FSS /ISS / PSL)... 10-15 seconds before LL, FSS starts to see some glitches, then more glitches starting ~5 sec before LL. ~30 second trends here.

Then zooming in ~100ms before LL (plot), maybe a small glitch is seen on ISS second loop PDs, and then the IMC loses lock. At the same time that the IMC loses lock, then lockloss pulse and AS port and LSC_REFL see the lock loss. So it seems like an IMC lockloss with some FSS glitching beforehand.

Images attached to this comment