Displaying report 1-1 of 1.
Reports until 18:42, Thursday 14 November 2024
H1 General (Lockloss, PSL)
corey.gray@LIGO.ORG - posted 18:42, Thursday 14 November 2024 - last comment - 09:23, Friday 15 November 2024(81286)
H1 Locking Status So Far: 2 Locklosses, one due to Alignment & one possibly FSS/IMC glitch (or not)

After tonight's Initial Alignment, H1's been fairly good with getting through the bulk of ISC_LOCK, but have had 2 consecutive locklosses a couple of states after MAX POWER: 

Locking Notes:

0003-0043 INITIAL ALIGNMENT (w/ ALSy needing touch up by hand)

0044 LOCK#1

LOCK #2:  DRMI looked its ugly self.  Needed to run CHECK MICH FRINGES and the BS was definitely the culprit for the nasty alignment and was fixed.  PRMI & DRMI both locked immediately.

Will continue locking for the next 2.5-3hrs, and then take H1 to IDLE and leave FSS & PMC -ON- for the night.

But if H1 makes it to NLN, will contact Louis or Joe B for a ~15min calibration check.

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 09:23, Friday 15 November 2024 (81290)

Vicky, Ryan, Sheila

Zooming in on this 2:05 UTC lockloss, MC2 trans dropped about 150ms after the IFO lost lock, so we think this was not due to the usual PSL/IMC issue, even though there was a glitch in the FSS right before the lockloss.

Images attached to this comment
Displaying report 1-1 of 1.