Reports until 16:04, Friday 15 November 2024
H1 ISC (Lockloss)
ibrahim.abouelfettouh@LIGO.ORG - posted 16:04, Friday 15 November 2024 - last comment - 16:23, Friday 15 November 2024(81301)
Lockloss 23:40 UTC

Ibrahim, Ryan S

Seems like an IMC lockloss. Interestingly, there was no obviously glitchy behavior (as previously observed) before or after the lockloss. Attached screenshot of ASC and IMC losing lock.

Images attached to this report
Comments related to this report
ryan.short@LIGO.ORG - 16:23, Friday 15 November 2024 (81302)

Adding more channels for the sake of investigation. As Ibrahim mentions, no glitchy behavior was seen leading up to this IMC lockloss, so this was either a large fast glitch out of nowhere or something else giving out. Seemingly all at once (or at least very close to each other), the FSS_FASTMON, RefCav trans, NPRO power, PMC high voltage, PMC mixer, and all IMC signals quickly change, so it's hard to tell which is truly happening first as there is lots of feedback between these signals.

Images attached to this comment