02:08utc NLN Lockloss due to FSS/IMC Glitch After 1hr Lock

Had about 20hrs with no IMC/FSS glitches from 9pm Thurs night until about 340pmPT Fri afternoon.  But have now had several for the last 5hrs.

Also for one ~60min stretch, H1 almost made it to NLN, but had rung up violins which kept us at OMC Whitening for 20min until the next IMC glitch.

Here are some running notes for the rough 5hrs filled with glitches (currently have H1 in IDLE).

Notes During Return of IMC/FSS Glitch Locklosses

2340utc (340pmPT) LOCKLOSS with IMC tag was the beginning of IMC/FSS glitch locklosses (where we went almost 20hrs since the last glitch around 5utc (9pmPT).

0111-0208:  OBSERVING

0208utc (608pmPT):  Attached screenshot shows a coincident glitch lockloss seen on FSS & IMC.  Here is the LOCKLOSS page also tagged with IMC glitch.

Starting an FRS Ticket to mark the DOWNTIME (FRS-32644) for 3.5hrs of DOWNTIME so far.  Where there was notable part of downtime due to IMC not locking easily.

VIOLINS Rung Up A Bit: (haven't had this since my shift on Tues night!)   So were stuck at OMC WHITENING for over 20min before H1 had....

So for the last 3hrs:

Not sure what is more useful.  Keep having ISC LOCK continue to locking, or to leave it in IDLE for IMC/PMC/FSS monitoring....