Reports until 07:35, Thursday 21 November 2024
H1 General
ryan.crouch@LIGO.ORG - posted 07:35, Thursday 21 November 2024 - last comment - 09:41, Thursday 21 November 2024(81394)
OPS Thursday DAY shift start

TITLE: 11/21 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Microseism
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: USEISM
    Wind: 3mph Gusts, 1mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.57 μm/s
QUICK SUMMARY:

Images attached to this report
Comments related to this report
victoriaa.xu@LIGO.ORG - 09:41, Thursday 21 November 2024 (81397)

As expected the FSS could not stay locked by itself. This overnight test was with O3 NRPO + the different power supply.

With only the laser+PMC+FSS, the PSL FSS unlocked >8 times overnight. Each time the bigger +/- 0.1 V PMC mixer glitches were observed. SQZ TTFSS fiber mixer also sees the PMC mixer glitches.

Images attached to this comment