Had to delay this measurement until 1pm locally due to a lockloss in the morning (coordinated with LLO [JoeH] to drop both H1 & L1 at the same time).
For this calibration, ran a non-standard measurement in that the simulines measurement was one Louis Dartez specifically requested be run for H1 (see below).
Measurement NOTES:
- Following instructions (link).....EXCEPT: For simulines measurement run this file per Louis D.'s request:
- " gpstime;python /ligo/groups/cal/src/simulines/simulines/simuLines.py -i /ligo/groups/cal/H1/simulines_settings/newDARM_20231221/settings_h1_20241005_lowerPcal_higherPUM.ini;gpstime "
- H1 at NLN for for over ~3hrs
- Calibration_Monitor medm screenshot is attached
- 2100 - 2132 Out of Observing, ISC LOCK to NLN_CAL_MEAS & Observatory Mode to CALIBRATION
- 2100 - 2106 Broadband measurement run
- Measurement at: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/
- 2106 - 2129 Simullines measurement
- gps START time: 1416431186.370596
- gps STOP time: 1416432611.142583
- Files writtten to subfolders here: /ligo/groups/cal/H1/measurements