I have found new damping settings for ETMY mode01 and ITMY mode05/06, which are given below,
ETMY01
Nominal - FM1+FM6+FM10, Gain = +0.1 (+30deg phase)
New - FM1+FM8+FM10, Gain = +0.1 (+60deg phase)
ITMY 05/06
Nominal - FM5+FM6+FM7+FM10, Gain = +0.02 (-30deg phase)
New - FM5+FM6+FM8+FM10, Gain = +0.01 (+30deg phase)
I have not made any changes in the lscparam file, will check these new settings for a few lock stretches (also let microseism to settle down) before making them final.
Tagging OpsInfo
So once Rahul is happy with the new Violin Mode settings for ETMy 01 & ITMy 05/06, Operators will need to enter his NEW settings by hand (this can be done any time after the DAMP_VIOLINS_FULL_POWER [566] state. For clarity, also attaching screenshots with the filter banks in question circled in light blue: