OPLEV charge measurements, ETMX, ETMY

On 11/12/24 Rahul ran the OPLEV charge measurements, I processed them this afternoon...

ETMY's charge seems to be slightly trending up in UL and LL but looks stagnant in UR. The charge is >= 50 V in LL_{P,Y} and UL_Y.

ETMX's charge looks to have a small upwards trend and is >= 50 V in all DOFs and quadrantss. The charge looks to have risen ~5-10 V in a little over a month over the DOFs and quadrants. The error in the measurement for EX is also larger than we usually see, the secondary microseism was elevated during these measurements.

Images attached to this report