Following instructions in alog79596, I took the opportunity this morning to calibrate the PSL rotation stage since it hasn't been done following the most recent NPRO swap.
The measurement file, new calibration fit, and screenshot of newly accepted SDFs are attached.
| Power in (W) | D | B (Minimum power angle) | C (Minimum power) | |
| Old Values | 97.433 | 1.990 | -24.797 | 0.000 |
| New Values | 94.944 | 1.990 | -24.793 |
0.000 |