Vicky had copied over the LLO PSAMS scan scripts into sqz/h1/scripts/SCAN_PSAMS.py, it turns up the gain on the SQZ ASC and turns off SQZ_ANG_ADJUST before stepping the ZM4/5 PSAMS (using the new 80685 servo) to values we gave it
We had to pause SQZ_MANAGER as it was not letting us bring SQZ_ANG_ADJUST to DOWN. Also worked by taking SQZ_MANAGER to SCAN_SQZ_ANG.
Future improvements: Repeat now we have the ASC on. Can we do this in anti-squeezing to be faster (hard to use ASC). Do we need to have the servo turn off SQZ_ANG_ADJUST and scan SQZ ang at each step or can we just leave the servo running?
We also turned the FC beam-spot control on to test it again while we are thermalizing (worked fine) and turned it off before finishing commissioning: reverted sdfs so H1:SQZ-FC_ASC_INJ_ANG_{P,Y}_OUTPUT are frozen a, edited sqzparams and reloaded.
We tried adjusting the Fc de-tuning H1:IOP-LSC0_RLF_FREQ_OFS, starting value 30deg. Tried 28, 32 and 34. Left FC detuning at 32. sdf here.