In the process of adding subsystem links to the ODC channels I came across some inconsistencies in the medm macro files: ISI: there exist currently /opt/rtcds/userapps/release/isi/common/medm/isibs_overview_macro.txt /opt/rtcds/userapps/release/isi/common/medm/isietmx_overview_macro.txt /opt/rtcds/userapps/release/isi/common/medm/isietmy_overview_macro.txt /opt/rtcds/userapps/release/isi/common/medm/isiham2_overview_macro.txt /opt/rtcds/userapps/release/isi/common/medm/isiham3_overview_macro.txt /opt/rtcds/userapps/release/isi/common/medm/isiham4_overview_macro.txt /opt/rtcds/userapps/release/isi/common/medm/isiham5_overview_macro.txt /opt/rtcds/userapps/release/isi/common/medm/isiham6_overview_macro.txt /opt/rtcds/userapps/release/isi/common/medm/isiitmx_overview_macro.txt /opt/rtcds/userapps/release/isi/common/medm/isiitmy_overview_macro.txt and /opt/rtcds/userapps/release/isi/h1/medm/bscisi/isibs_overview_macro.txt /opt/rtcds/userapps/release/isi/h1/medm/bscisi/isietmx_overview_macro.txt /opt/rtcds/userapps/release/isi/h1/medm/bscisi/isiitmx_overview_macro.txt /opt/rtcds/userapps/release/isi/h1/medm/bscisi/isiitmy_overview_macro.txt /opt/rtcds/userapps/release/isi/h1/medm/bscisi/isitst_overview_macro.txt /opt/rtcds/userapps/release/isi/h1/medm/hamisi/isiham2_overview_macro.txt /opt/rtcds/userapps/release/isi/h1/medm/hamisi/isiham3_overview_macro.txt /opt/rtcds/userapps/release/isi/h1/medm/hamisi/isiham4_overview_macro.txt /opt/rtcds/userapps/release/isi/h1/medm/hamisi/isiham5_overview_macro.txt /opt/rtcds/userapps/release/isi/h1/medm/hamisi/isiham6_overview_macro.txt /opt/rtcds/userapps/release/isi/h1/medm/hepi/hepiham1_overview_macro.txt and /opt/rtcds/userapps/release/isi/l1/medm/bscisi/L1_isibs_overview_macro.txt /opt/rtcds/userapps/release/isi/l1/medm/bscisi/L1_isietmx_overview_macro.txt /opt/rtcds/userapps/release/isi/l1/medm/bscisi/L1_isietmy_overview_macro.txt /opt/rtcds/userapps/release/isi/l1/medm/bscisi/L1_isiitmx_overview_macro.txt /opt/rtcds/userapps/release/isi/l1/medm/bscisi/L1_isiitmy_overview_macro.txt /opt/rtcds/userapps/release/isi/l1/medm/hamisi/L1_isiham2_overview_macro.txt /opt/rtcds/userapps/release/isi/l1/medm/hamisi/L1_isiham3_overview_macro.txt /opt/rtcds/userapps/release/isi/l1/medm/hamisi/L1_isiham4_overview_macro.txt /opt/rtcds/userapps/release/isi/l1/medm/hamisi/L1_isiham5_overview_macro.txt /opt/rtcds/userapps/release/isi/l1/medm/hamisi/L1_isiham6_overview_macro.txt more that 1) h1 and l1 files are named differently and 2) some common files exist SEI needs to sort out which ones we need to use Also, for HPI, there exist: /opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepibs_overview_macro.txt /opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham1_overview_macro.txt /opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham2_overview_macro.txt /opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham3_overview_macro.txt /opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham4_overview_macro.txt /opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham5_overview_macro.txt /opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiham6_overview_macro.txt /opt/rtcds/userapps/release/hpi/h1/medm/hepi/hepiitmy_overview_macro.txt and /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpibs_overview_macro.txt /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpietmx_overview_macro.txt /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpietmy_overview_macro.txt /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham1_overview_macro.txt /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham2_overview_macro.txt /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham3_overview_macro.txt /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham4_overview_macro.txt /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham5_overview_macro.txt /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiham6_overview_macro.txt /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiitmx_overview_macro.txt /opt/rtcds/userapps/release/hpi/l1/medm/hepitemplate/L1_hpiitmy_overview_macro.txt Note that 1) they have different name structures at the different sites 2) not all files exist for hanford 3) they are in different sub-directories ======================== I plead for standardization and sanity!
As far as I know, the reason why we have site specific safe.snap is due to Livingston inconsistency with the design wiring diagram. It is on the to-do list.