PSL Weekly Report - Weekly FAMIS 26329

Closes FAMIS 26329, Last checked in alog 81539


Laser Status:
    NPRO output power is 1.849W
    AMP1 output power is 70.27W
    AMP2 output power is 137.2W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 11 days, 16 hr 6 minutes
    Reflected power = 22.82W
    Transmitted power = 105.8W
    PowerSum = 128.7W

FSS:
    It has been locked for 0 days 0 hr and 21 min
    TPD[V] = 0.8091V

ISS:
    The diffracted power is around 3.4%
    Last saturation event was 0 days 0 hours and 21 minutes ago


Possible Issues: None reported