Displaying report 1-1 of 1.
Reports until 14:29, Monday 09 December 2024
H1 SEI (SEI)
ibrahim.abouelfettouh@LIGO.ORG - posted 14:29, Monday 09 December 2024 (81707)
SEI seismometer mass check - Monthly FAMIS 26496

SEI seismometer mass check - Monthly - Closes FAMIS 26496. Last Checked alog 80959

T240

Averaging Mass Centering channels for 10 [sec] ...
2024-12-09 14:00:13.262669


There are 14 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.751 [V]
ETMX T240 2 DOF Y/V = -0.833 [V]
ETMX T240 2 DOF Z/W = -0.352 [V]
ITMX T240 1 DOF X/U = -1.576 [V]
ITMX T240 1 DOF Y/V = 0.388 [V]
ITMX T240 1 DOF Z/W = 0.488 [V]
ITMX T240 2 DOF Y/V = 0.308 [V]
ITMX T240 3 DOF X/U = -1.657 [V]
ITMY T240 3 DOF X/U = -0.762 [V]
ITMY T240 3 DOF Z/W = -2.097 [V]
BS T240 1 DOF Y/V = -0.329 [V]
BS T240 3 DOF Z/W = -0.41 [V]
HAM8 1 DOF Y/V = -0.415 [V]
HAM8 1 DOF Z/W = -0.7 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = 0.049 [V]
ETMX T240 1 DOF Y/V = 0.002 [V]
ETMX T240 1 DOF Z/W = 0.005 [V]
ETMX T240 3 DOF X/U = 0.029 [V]
ETMX T240 3 DOF Y/V = -0.001 [V]
ETMX T240 3 DOF Z/W = 0.014 [V]
ETMY T240 1 DOF X/U = 0.092 [V]
ETMY T240 1 DOF Y/V = 0.202 [V]
ETMY T240 1 DOF Z/W = 0.263 [V]
ETMY T240 2 DOF X/U = -0.032 [V]
ETMY T240 2 DOF Y/V = 0.233 [V]
ETMY T240 2 DOF Z/W = 0.071 [V]
ETMY T240 3 DOF X/U = 0.286 [V]
ETMY T240 3 DOF Y/V = 0.127 [V]
ETMY T240 3 DOF Z/W = 0.184 [V]
ITMX T240 2 DOF X/U = 0.182 [V]
ITMX T240 2 DOF Z/W = 0.29 [V]
ITMX T240 3 DOF Y/V = 0.175 [V]
ITMX T240 3 DOF Z/W = 0.134 [V]
ITMY T240 1 DOF X/U = 0.111 [V]
ITMY T240 1 DOF Y/V = 0.129 [V]
ITMY T240 1 DOF Z/W = -0.006 [V]
ITMY T240 2 DOF X/U = 0.059 [V]
ITMY T240 2 DOF Y/V = 0.218 [V]
ITMY T240 2 DOF Z/W = 0.147 [V]
ITMY T240 3 DOF Y/V = 0.099 [V]
BS T240 1 DOF X/U = -0.127 [V]
BS T240 1 DOF Z/W = 0.157 [V]
BS T240 2 DOF X/U = -0.014 [V]
BS T240 2 DOF Y/V = 0.072 [V]
BS T240 2 DOF Z/W = -0.057 [V]
BS T240 3 DOF X/U = -0.136 [V]
BS T240 3 DOF Y/V = -0.284 [V]
HAM8 1 DOF X/U = -0.298 [V]


Assessment complete.
 


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.133 [V]
ETMX T240 1 DOF Y/V = -0.112 [V]
ETMX T240 1 DOF Z/W = -0.159 [V]
ETMX T240 3 DOF X/U = -0.1 [V]
ETMX T240 3 DOF Y/V = -0.226 [V]
ETMX T240 3 DOF Z/W = -0.103 [V]
ETMY T240 1 DOF X/U = 0.022 [V]
ETMY T240 1 DOF Y/V = 0.09 [V]
ETMY T240 1 DOF Z/W = 0.148 [V]
ETMY T240 2 DOF X/U = -0.098 [V]
ETMY T240 2 DOF Y/V = 0.152 [V]
ETMY T240 2 DOF Z/W = 0.049 [V]
ETMY T240 3 DOF X/U = 0.155 [V]
ETMY T240 3 DOF Y/V = 0.041 [V]
ETMY T240 3 DOF Z/W = 0.089 [V]
ITMX T240 1 DOF Z/W = -0.092 [V]
ITMX T240 3 DOF Z/W = -0.289 [V]
ITMY T240 1 DOF X/U = -0.25 [V]
ITMY T240 2 DOF X/U = -0.08 [V]
ITMY T240 2 DOF Y/V = -0.185 [V]
HAM8 1 DOF X/U = -0.287 [V]
Assessment complete.

STS

Averaging Mass Centering channels for 10 [sec] ...


2024-12-09 14:00:32.260633
There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -2.37 [V]


All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.472 [V]
STS A DOF Y/V = -0.961 [V]
STS A DOF Z/W = -0.448 [V]
STS B DOF X/U = 0.281 [V]
STS B DOF Y/V = 0.954 [V]
STS B DOF Z/W = -0.387 [V]
STS C DOF X/U = -0.777 [V]
STS C DOF Y/V = 0.737 [V]
STS C DOF Z/W = 0.654 [V]
STS EX DOF X/U = -0.145 [V]
STS EX DOF Y/V = -0.044 [V]
STS EX DOF Z/W = 0.139 [V]
STS EY DOF Y/V = 0.035 [V]
STS EY DOF Z/W = 1.273 [V]
STS FC DOF X/U = 0.216 [V]
STS FC DOF Y/V = -1.054 [V]
STS FC DOF Z/W = 0.66 [V]


Assessment complete.
 

Displaying report 1-1 of 1.