Reports until 14:15, Tuesday 10 December 2024
H1 SUS
oli.patane@LIGO.ORG - posted 14:15, Tuesday 10 December 2024 - last comment - 16:44, Monday 16 December 2024(81736)
In-Lock SUS Charge Measurements for December 10th FAMIS

Closes FAMIS#28383, last checked 81688

Once again, the coherence for ITMX bias drive bias off is below the coherence threshold - this time the coherence is 0.01, much lower than the threshold of 0.1, so there are once again no new analyzed measurements for ITMX.

ETMX, ETMY, ITMX, ITMY

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 16:44, Monday 16 December 2024 (81858)

Checked that the measurements for ITMX bias are running and the same magnitude for bias in and bias off. They are at a lower magnitude than the quadrant injection on the ESDAMON/LVEASDAMON  so we could think about increasing the magnitude if we are not happy with the 81688 no charge build-up on the test mass conclusion. We also still have a pending "to do" from Vlad in 79597: explicitly cast DARM data to np.float64

Images attached to this comment