TITLE: 12/11 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 102Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY: Currently Observing and have been Locked for almost 5 hours.  Our range is still all over the place unfortunately. I jumped in and out of Observing a few times by turning squeezing on and off to check for differences with the range (81753), but didn't find anything.
LOG:

00:30 Relocking
01:08 NOMINAL_LOW_NOISE
01:14 Observing

    02:57 Went out of Observing and turned off SQZ to see if that fixes the mystery noise 
    03:09 Back to FDS
    03:19 Turned off SQZ
    03:33 Back to FDS and back to Observing

Comments related to this report
camilla.compton@LIGO.ORG - 09:04, Wednesday 11 December 2024 (81760)ISC, SQZ

Attached plot shows that the low range glitchy behavior happens independent of whether we have SQZ injected or not. Traces show the SQZ/NO SQZ times Oli noted in green/yellow with comparisons of good SQZ and NO SQZ times in blue and red.

  • Light and dark green = Squeezing injected. Can see 20-100Hz noise.
  • Yellow and orange = NO SQZ. Can still see 20-100Hz noise.
  • Blue = Squeezing injected. Good stable range.
  • Red = NO SQZ. No noise.

Yesterday, in 81724 it seemed like the behavior stopped before we took the no SQZ time. Each trace is: 0.1Hz 50% overlap 100 averages = 500 seconds ~10 minutes. /ligo/home/camilla.compton/Documents/H1_DARM_FOM_s_glitchy.xml

Conclusions:

  • The injected squeezed light or any backscatter from HAM7/8 in not causing low range times
  • Could still be a SQZ electronics issue? Due to hveto work that Detchar and gravity spy are doing linking to SQZ channels, links in chat and pasted here: hveto/Dec9/no_sqz/, wandering lines SQZ-FC, lines CO2, gravityspy, 20241209/detchar/hveto/,  81730, 81587
  • Even in good range times, SQZ is added noise 20-40Hz (compare red to blue): could retune FC de-tuning to improve.
Images attached to this comment
camilla.compton@LIGO.ORG - 10:59, Wednesday 11 December 2024 (81762)

I ran BRUCOs on the bad (1417932916: 2024/12/11 06:14UTC) and good (1417949016: 2024/12/11 10:43UTC) times in the attached plot. 

Main differences in 20-100Hz region: