Reports until 11:04, Friday 13 December 2024
H1 CDS
david.barker@LIGO.ORG - posted 11:04, Friday 13 December 2024 (81813)
EX timing checks are no longer needed, Daniel updated Beckhoff to new Timing Card version numbers

Follow up from Tuesday maintenance: Daniel upgraded the Beckhoff slow controls software to no longer error on a version mismatch for the new timing cards installed in h1susex and h1omc0 (for new LIGO DAC and variable Duo-Tone frequency respectively).

I have changed the CDS HW stat code to no longer check that the EX timing error was solely due to the version mismatch. I also reverted the SYS_TC3_TIMING.adl file, removing the temporary blurb I had put in there explaining the expected EX error.

I took the opportunity to upgrade the timing entry on the CDS Overview to a system block. This will turn RED if there are any timing errors, or MAGENTA is the timing system freezes. Clicking on it opens the timing overview, please see attached.

Images attached to this report