Closes FAMIS#28383, last checked 81688
Once again, the coherence for ITMX bias drive bias off is below the coherence threshold - this time the coherence is 0.01, much lower than the threshold of 0.1, so there are once again no new analyzed measurements for ITMX.
Checked that the measurements for ITMX bias are running and the same magnitude for bias in and bias off. They are at a lower magnitude than the quadrant injection on the ESDAMON/LVEASDAMON so we could think about increasing the magnitude if we are not happy with the 81688 no charge build-up on the test mass conclusion. We also still have a pending "to do" from Vlad in 79597: explicitly cast DARM data to np.float64