Reports until 10:16, Monday 21 October 2013
X1 SUS
jeffrey.bartlett@LIGO.ORG - posted 10:16, Monday 21 October 2013 - last comment - 08:12, Tuesday 22 October 2013(8191)
Phase 1b Testing 3IFO-OMC
    On Friday I took the transfer function and power spectra data for phase 1b testing of the 3IFO-OMC suspension. The data has been plotted and compares favorably with the already pass Phase 1b testing data from H1-OMC. The plots are attached below and are ready for review by the testing group.  
Non-image files attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 10:48, Monday 21 October 2013 (8192)

Results look good, and are approved for phase 1b

stuart.aston@LIGO.ORG - 08:12, Tuesday 22 October 2013 (8206)
Agree, no concerns at all, a really nice and clean set of measurements!

Great work the assembly and testing team!