Displaying report 1-1 of 1.
Reports until 03:46, Sunday 22 December 2024
H1 General (GRD, SUS)
oli.patane@LIGO.ORG - posted 03:46, Sunday 22 December 2024 (81943)
OWL Intervention

I was called to intervene with the detector and found that we were in NLN but couldn't get into Observing because of an SDF diff on the ramp time for the ETMY Lock ESD bias. When TJ and I were testing out the code for the function that generates the INCREASE/DECREASE BIAS states for SUS_PI, we had decided on leaving the line in that sets the bias ramp time to 30 for going from a bias offset of -9 back to the nominal bias of -4.9. We thought it would be fine because the ramp time would get reverted when we lost lock, but we forgot about the part where we have to go back into Observing after the PI gets damped at the higher bias (oops). At least it was me who had to intervene so I can suffer the consequences of my mistakes! I changed that line in the code(attachment) so that when we are going from the higher bias to the nominal lower bias, the ramp time is the nominal 120 seconds. So it'll take longer to ramp back to nominal bias, but at least we'll be able to go back to Observing!

Images attached to this report
Displaying report 1-1 of 1.