Reports until 13:12, Monday 21 October 2013
H1 ISC
corey.gray@LIGO.ORG - posted 13:12, Monday 21 October 2013 - last comment - 10:55, Friday 03 October 2014(8196)
Final Two TMS QPD In-Vac Cables Connected To Chamber

After consulting with Keita and TMS group, we finalized where we wanted the QPD cables to go [we have to be EXTREMELY careful with cabling the QPDs because if the wrong cable is connected to these guys we run the risk of frying the QPDs---several QPDs were damaged during the H2 TMS Installation].  Basically, we stuck with what the drawing (D1300007) calls out.  But I made sure to clearly label the external flanges to where the QPDs are connected (see photo).

Below is the latest cable run-thru with Flanges noted:

In-Air Cable

Chamber 

feed-thru

In-vac cable Cable Bracket In-Vac Cable

Cable Bracket

on TMS

In-Vac Component
H1:SUS_BSC9_TMONX-1("SUS1") .....|E6-7C1|..... D1000225 s/n S1106816 CB3, 1st floor D1000234 s/n V2-96-903 --- OSEMS:  Face1, Face2, Face3, Left
H1:SUS_BSC9_TMONX-4("SUS2") .....|E6-7C2|..... D1000225 s/n S1106771 CB3, 2nd floor D1000234 s/n V2-88-934 --- OSEMS:  Right, Side, ---, ---
: In-Air cable not run yet : .....|E4-2C1|..... D1000924 s/n S1104104 CB6, 1st floor D1000568 s/n S1104110 CB-primary, 1st floor Green QPD (D1000231 s/nS1202413)
: In-Air cable not run yet : .....|E4-1C2|..... D1000924 s/n S1203963 CB6, 2nd floor D1000568 s/n S1202739 CB-primary, 2nd floor Red QPD (D1000231 s/nS1202411)
: In-Air cable not run yet : .....|E4-1C1|..... D1000223 s/n S1202653 CB5, 1st floor D1000921 s/n S1104112* CB-entry, 2nd floor Picomotors (D1000238 s/n S1105218)
: In-Air cable not run yet : .....|E4-2C2|..... D1000223 s/n S1202656 CB5, 2nd floor D1000921 s/n S1104113 CB-entry, 1st floor Beam Diverter (D1000237 s/n S1202724)

 

 

	
in-vac cable cable bracket in-vac cable in-vac component
H1:SUS_BSC9_TMONX-1("SUS1")
in-vac cable cable bracket in-vac cable in-vac component
H1:SUS_BSC9_TMONX-1("SUS1")

 

 

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 10:55, Friday 03 October 2014 (14289)

ICS Note:  D1000225 s/n S1106771 is not in ICS :-/