Thurs EVE Ops Summary

TITLE: 12/27 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Wind
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:

Bit of a frustrating shift with H1 losing lock most of the time at the same point late in the ISC_LOCKing scheme (alog 82000).  Plus dealing with high seismic motion (microseism is still around 1um/sec).  No alignments were run or needed this shift.  With locking, made it fairly repeatedly all the way up to around TRANSITION_FROM_ETMX / LOWNOISE_ESD_ETMX for majority of shift's locklosses.  For relocking, DRMI generally looks horrible, but PRMI does the trick for continuing on beyond DRMI---hence no Initial Alignments have been run this evening.

And shift ends with a M5.9 mid-Atlantic earthquake rolling through.