At 21:58 VACSTAT issued a BSC3 alert, which looks like it could be a sensor spike. 1 minute later PT110 (HAM6) sensor went offline to flat 0.0Torr.
VACSTAT restarted and PT110B removed from the gauge list.
Pressure trend for BSC3 (PT132) and HAM6 (PT110) trends. BSC glitch 21:56:48, HAM6 dropout 21:59:24
BSC3 sensor glitch at 06:59:43, could be related to HAM6 issue, these are the same type of gauge. I restarted VACSTAT at 08:05 to clear this, it is again running with HAM6 PT110 DISABLED.