Reports until 22:23, Thursday 26 December 2024
H1 CDS
david.barker@LIGO.ORG - posted 22:23, Thursday 26 December 2024 - last comment - 08:09, Friday 27 December 2024(82005)
VACSTAT reports BSC3 and HAM6 issues

At 21:58 VACSTAT issued a BSC3 alert, which looks like it could be a sensor spike. 1 minute later PT110 (HAM6) sensor went offline to flat 0.0Torr.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 22:37, Thursday 26 December 2024 (82006)

VACSTAT restarted and PT110B removed from the gauge list.

Images attached to this comment
david.barker@LIGO.ORG - 22:59, Thursday 26 December 2024 (82007)

Pressure trend for BSC3 (PT132) and HAM6 (PT110) trends. BSC glitch 21:56:48, HAM6 dropout 21:59:24

Images attached to this comment
david.barker@LIGO.ORG - 08:09, Friday 27 December 2024 (82009)

BSC3 sensor glitch at 06:59:43, could be related to HAM6 issue, these are the same type of gauge. I restarted VACSTAT at 08:05 to clear this, it is again running with HAM6 PT110 DISABLED.

Images attached to this comment