TITLE: 01/01 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 159Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY:
01:12 UTC Superevent S250101k candidate!
2:04 UTC PI mode 29 has been slightly elevated for the past 10 minutes.
H1: SUS-ETMX_PI_ESD_DRIVER_OUT_RIGHT_MON seems like its being driven at close to it's maximum.
No verbal alarm announced yet and it doesn't seem to be causing any problems.
2:16 UTC SQZ Manager not in nominal state. Dropped from Observing.
SQZ_MANAGER dropped to LOCK_PMC and took around 4 minutes to regain lock.
2:22 UTC H1 Back into Observing.
Checking back in on this PI mode 29 at 5:46 UTC PI Verbal Alarm still not alraming, but it doesn't seem to be negatively impacting the DCPD readouts, sensitivity, and we've now been locked for 13 + Hours.
Happy new year!