Reports until 11:26, Thursday 02 January 2025
LHO VE
david.barker@LIGO.ORG - posted 11:26, Thursday 02 January 2025 - last comment - 11:39, Thursday 02 January 2025(82084)
Thu CP1 Fill

Thu Jan 02 10:04:52 2025 INFO: Fill completed in 4min 49secs

Travis confirmed a good fill curbside. TCAmin = -50.1C, trip = -50.0C, OAT [3C, 37F]. Travis knocked some ice off the thermocouples.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 11:39, Thursday 02 January 2025 (82085)

I did a linear fit of the TCA starting temp (at 09:59:00 each day) and the TCA minimum over the following 30 minutes.

Attached plot show the fit for the past 14 days, X=starting_temp, Y=min_temp.

When the starting temp goes into the positive C region, the fit becomes more linear.

Fit is:

Tmin = 1.57*Tstart - 97.87

Images attached to this comment