Closes FAMIS#26497, last checked 81707
T240 (channels averaged between 2025-01-03 17:24:45-17:24:55 UTC)
There are 15 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.812 [V]
ETMX T240 2 DOF Y/V = -0.874 [V]
ETMX T240 2 DOF Z/W = -0.445 [V]
ITMX T240 1 DOF X/U = -1.647 [V]
ITMX T240 1 DOF Y/V = 0.37 [V]
ITMX T240 1 DOF Z/W = 0.478 [V]
ITMX T240 3 DOF X/U = -1.719 [V]
ITMY T240 3 DOF X/U = -0.818 [V]
ITMY T240 3 DOF Z/W = -2.148 [V]
BS T240 1 DOF Y/V = -0.369 [V]
BS T240 3 DOF Y/V = -0.318 [V]
BS T240 3 DOF Z/W = -0.458 [V]
HAM8 1 DOF X/U = -0.305 [V]
HAM8 1 DOF Y/V = -0.413 [V]
HAM8 1 DOF Z/W = -0.701 [V]
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = 0.005 [V]
ETMX T240 1 DOF Y/V = 0.001 [V]
ETMX T240 1 DOF Z/W = 0.002 [V]
ETMX T240 3 DOF X/U = 0.027 [V]
ETMX T240 3 DOF Y/V = -0.052 [V]
ETMX T240 3 DOF Z/W = 0.011 [V]
ETMY T240 1 DOF X/U = 0.118 [V]
ETMY T240 1 DOF Y/V = 0.193 [V]
ETMY T240 1 DOF Z/W = 0.261 [V]
ETMY T240 2 DOF X/U = -0.045 [V]
ETMY T240 2 DOF Y/V = 0.229 [V]
ETMY T240 2 DOF Z/W = 0.094 [V]
ETMY T240 3 DOF X/U = 0.285 [V]
ETMY T240 3 DOF Y/V = 0.154 [V]
ETMY T240 3 DOF Z/W = 0.173 [V]
ITMX T240 2 DOF X/U = 0.164 [V]
ITMX T240 2 DOF Y/V = 0.286 [V]
ITMX T240 2 DOF Z/W = 0.257 [V]
ITMX T240 3 DOF Y/V = 0.145 [V]
ITMX T240 3 DOF Z/W = 0.121 [V]
ITMY T240 1 DOF X/U = 0.087 [V]
ITMY T240 1 DOF Y/V = 0.104 [V]
ITMY T240 1 DOF Z/W = -0.034 [V]
ITMY T240 2 DOF X/U = 0.049 [V]
ITMY T240 2 DOF Y/V = 0.202 [V]
ITMY T240 2 DOF Z/W = 0.119 [V]
ITMY T240 3 DOF Y/V = 0.081 [V]
BS T240 1 DOF X/U = -0.17 [V]
BS T240 1 DOF Z/W = 0.113 [V]
BS T240 2 DOF X/U = -0.056 [V]
BS T240 2 DOF Y/V = 0.031 [V]
BS T240 2 DOF Z/W = -0.112 [V]
BS T240 3 DOF X/U = -0.182 [V]
STS (channels averaged between 2025-01-03 17:24:58-17:25:08 UTC)
There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -2.435 [V]
All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.503 [V]
STS A DOF Y/V = -0.832 [V]
STS A DOF Z/W = -0.538 [V]
STS B DOF X/U = 0.276 [V]
STS B DOF Y/V = 0.948 [V]
STS B DOF Z/W = -0.379 [V]
STS C DOF X/U = -0.766 [V]
STS C DOF Y/V = 0.749 [V]
STS C DOF Z/W = 0.63 [V]
STS EX DOF X/U = -0.14 [V]
STS EX DOF Y/V = -0.012 [V]
STS EX DOF Z/W = 0.059 [V]
STS EY DOF Y/V = 0.059 [V]
STS EY DOF Z/W = 1.312 [V]
STS FC DOF X/U = 0.21 [V]
STS FC DOF Y/V = -1.065 [V]
STS FC DOF Z/W = 0.661 [V]