| OSEM NAME | Open Light Value | Norm Gain | Offset | |
| M1 T1 | 27421 | 1.094 | -13710 | |
| M1 T2 | 25821 | 1.162 | -12910 | |
| M1 T3 | 29178 | 1.028 | -14589 | |
| M1 LF | 28371 | 1.057 | -14186 | |
| M1 RT | 26593 | 1.128 | -13296 | |
| M1 SD | 26239 | 1.143 | -13120 | |
| M2 UL | 28808 | 1.041 | -14404 | |
| M2 LL | 26899 | 1.115 | -13450 | |
| M2 UR | 28198 | 1.064 | -14099 | |
| M2 LR | 25501 | 1.176 | -12750 | |
| M3 UL | 27664 | 1.084 | -13832 | |
| M3 LL | 28342 | 1.058 | -14171 | |
| M3 UR | 26913 | 1.115 | -13456 | |
| M3 LR | 25444 | 1.179 | -12722 |
Gains and offsets to center and normalize the signal of the osem between -15000 and 15000 counts have been calculated and are summed up in the summary table above.
Numbers have been entered in the medm and a new safe snapshot has been commited to the svn.
The excel chart E1200343 has been updated as well