Displaying report 1-1 of 1.
Reports until 15:41, Tuesday 22 October 2013
H1 AOS
stefan.ballmer@LIGO.ORG - posted 15:41, Tuesday 22 October 2013 (8213)
RTCG dependencies scripts in cds/common/scripts
Added the following scripts to cds/common/scripts
checkCompiledModel      : list all targets that use the specified model or library
checkTargetDependencies : list all models or libraries for specified target
dumpTargetDependencies  : simplified output of the above (requested by Jeff)

Example:
1) find all dependencies of h1susbs

>>checkTargetDependencies h1susbs

.mdl files:
Modify tag of model                         | Model name | SVN tag
=============================================================================
LastModifiedDate "Tue Jun 19 15:09:01 2012" | ODC.mdl |
LastModifiedDate "Tue May 7 14:11:17 2013" | h1susbs.mdl |
LastModifiedDate "Wed Jan 25 14:43:23 2012" | SIXOSEM_F_COILOUTF_MASTER.mdl |
LastModifiedDate "Thu Oct 6 15:33:48 2011" | FOUROSEM_COILOUTF_MASTER.mdl |
LastModifiedDate "Tue Aug 23 15:03:24 2011" | FOUROSEM_WD_AC_MASTER.mdl |
LastModifiedDate "Wed Aug 1 16:30:24 2012" | STATE_BIO_MASTER.mdl |
LastModifiedDate "Tue Oct 2 16:57:07 2012" | FOUROSEM_STAGE_MASTER.mdl |
LastModifiedDate "Thu Oct 11 09:59:06 2012" | SIXOSEM_F_STAGE_MASTER.mdl |
LastModifiedDate "Fri Sep 16 20:01:12 2011" | SIXOSEM_F_WD_DC_MASTER.mdl |
LastModifiedDate "Fri Sep 16 20:01:37 2011" | SIXOSEM_F_WD_AC_MASTER.mdl |
LastModifiedDate "Sun Oct 14 19:03:50 2012" | BSFM_MASTER.mdl |
LastModifiedDate "Wed Sep 7 14:37:51 2011" | FOUROSEM_WD_DC_MASTER.mdl |
LastModifiedDate "Fri Jun 7 16:34:37 2013" | QPD.mdl |
LastModifiedDate "Thu Feb 2 09:58:37 2012" | ISC_common.mdl |
Dependencies other than .mdl files:
=============================================================================
src files:
cds/common/src/ODC_ADD_PARITY.c
sus/common/src/CD_STATE_MACHINE.c
sus/common/src/WATCHDOG.c
=============================================================================

2) find all targets using QPD.mdl

>>checkCompiledModel QPD.mdl
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1ascimc |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1asc |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1iscex |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1iscey |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1psliss |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susbs |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susbstst |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susetmx |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susetmy |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susitmx |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susitmy |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1suspr3 |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1susquadtst |
QPD.mdl | LastModifiedDate "Fri Jun 7 16:34:37 2013" | h1sussr3 |

Displaying report 1-1 of 1.