Sheila, Camilla
After TJ found out OPO was struggling to get enough SHG pump power to lock 82196, Sheila repeated Daniel's 82057 SHG work as he had increased H1:SQZ-SHG_GR_DC_POWERMON from 95 to 125mW but now it's down to 92mW: Tried steering the beam with picos moves, and by adjusting the temperature it improved to 93mW only.
We went only SQZT0 and Sheila adjusted the alignment into the OPO pump fiber with the OPO unlocked, bringing the the OPO REFL DC power from 1.7 to 1.9mW. We also moved the SHG wave plate further to maximize the amount of light Now CLF could lock with controlmon around 5.8V. Much better and closer to the center of the range so should avoid this mornings 82196 issues.
Homdyne Work:
To take the below data, SEED power reduced back to 0.6mW, and then:
| Type | NLG | SQZ dB @ 1kHz | Angle | DTT Ref | Notes |
| Dark Noise | N/A | N/A | ref 0 | This and shot noise was noisy <300Hz at times when the OPO was locking or scanning, unsure why. | |
| ASQZ | 11.2 | 14.2 | 241 | ref 2 | opo_grTrans_setpoint_uW = 80uW |
| SQZ | 11.2 | -6.8 | 154 | ref 3 | reduced LO loop gain from 15 to -1 |
| SQZ | 14.3 | -6.1 | 182 | ref 4 |
opo_grTrans_setpoint_uW = 120uW
reduced LO loop gain from -1 to -12
|
| ASQZ | 14.3 | 17.8 | 216 | ref 5 | |
| ASQZ | 16.0 | 19.1 | 210 | ref 6 | opo_grTrans_setpoint_uW = 140uW |
| SQZ | 16.0 | 191 | ref 7 | ||
| SQZ | 16.0 | -6.8 | 190 | ref 8 | increased LO loop gain from -12 to -1 as was looking peaky |
| Shot Noise | N/A | N/A | ref 1 |
Blocked SEED, LO only.
|
We measured ~6.5dB of SQZ on the HD and up to 19dB of ASQZ. Plot attached.
Next time we work on the HD, we should measure the LO loop to know the correct gain to use.
SQZ data set
| UTC | Type | CLF Phase | DTT ref |
| 19:02:00 - 19:08:00 | No SQZ | N/A | ref 0 |
| 19:14:00 - 19:20:00 (6mins) | FDS SQZ | 177deg | ref 1 |
| 19:21:00 - 19:25:00 (4mins) | FDS Mid + SQZ | 215deg | ref 2 |
| 19:26:00 - 19:30:00 (4mins) | FDS Mid - SQZ | 125deg | ref 3 |
| 19:32:00 - 19:36:00 (4mins) | FDS ASQZ | (-sign) 108deg | ref 4 |
| 19:40:00- 19:43:00 (3mins) | FIS ASQZ | (-sign) 108deg | ref 5 |
| 19:43:15- 19:45:15 (2mins) | FIS ASQZ +10deg | (-sign) 118deg | ref 6 |
|
19:45:30- 19:47:30 (2mins)
|
FIS ASQZ -10deg
|
(-sign) 98deg
|
ref 7
|
|
19:48:00 - 19:51:00 (3mins)
|
FIS SQZ
|
177deg
|
ref 8
|
|
19:51:30 - 19:54:30 (3mins)
|
FIS Mid + SQZ
(check, small low freq glitch at 19:53:49)
|
215deg
|
ref 9
|
|
19:55:00 - 19:58:00 (3mins)
|
FIS Mid - SQZ
|
125deg
|
ref 10
|
In 83022 we found that we had pump depletion during these measurements so that the OPO trs powers were actually lower than reported
I've imported Camilla's data from dtt, subtracted the dark noise. As Camilla notes above, the NLG measurements here don't nicely fit a model for a consistent threshold power. Instead of using the NLG data, I've allowed the threshold power to be one of the parameters that varies in the fit, along with total efficiency and phase noise. In principle one could also use this data to estimate the technical nosie that limits squeezing, but I haven't tried that with just a few points here.
The attached shows the NLG measurements vs what we would expect given the threshold power that the squeezing and anti-squeezing fits suggest. This model suggests that the total efficiency to of the homodyne squeezing is only only 81%, which seems too low.
This script is available here: quantumnoisebudgeting, but needs a lot of cleaning up.