BSC 9 Actuator Attachment

Both horizontal and vertical HEPI actuators are attached on BSC 9.

Values after IAS positing, pre actuator attachment:

Initial 1 2 3 4
X .532 -- -- .623
Y .203 .329 .636 .542
Z .419 .430 .406 .474

After actuator attachment:

Install 1 2 3 4
X .527 -- -- .615
Y .196 .329 .637 .546
Z .416 .424 .412 .483

Change

Delta 1 2 3 4
X -.005 (N) -- -- -.008 (N)
Y -.007 (W) 0 +.001 (W) +.004 (W)
Z -.003 (U) -.006 (U) +.006 (D) +.009 (D)

Corner 4's big vertical change was possibly from a tripod with some bend in it.