TITLE: 01/14 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Currently relocking, we just lost lock at LOWNOISE_ESD_ETMX.
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 22:08 | OPS | LVEA | LVEA | N | LASER SAFE | 16:01 |
| 15:48 | FAC | Kim, Nelly | EX | n | Tech clean | 16:46 |
| 16:01 | FAC | Chris | XARM | n | Big Green versus tumbleweeds, finished at 23:00 | 17:02 |
| 16:16 | CAL | Sheila | CR | n | IM4 trans cal check | 17:01 |
| 16:17 | Camilla, Mitchell | LVEA (WB) | n | Looking for parts | 16:24 | |
| 16:31 | VAC | Janos, Jordan, Travis, JC | MX, EX | n | Air supply replacement | 22:36 |
| 16:39 | PSL | Mayank, Sivananda, Rick, Rahul, Keita | LVEA (H2 PSL+tour) | n | Grabbing parts (Keita out 18:21) | 18:48 |
| 16:40 | PCAL | Tony | PCAL Lab | y(local) | Preparing stuff to ship | 17:31 |
| 16:47 | FAC | Kim, Nelly | EY | n | Tech clean | 18:09 |
| 16:48 | EE | Fil | CER | n | Checking for OMC0 necessities | 17:05 |
| 16:52 | Christina | OSB Receiving | n | Forklifting stuff into the bins | 18:01 | |
| 17:04 | FAC | Chris, pest control | LVEA, EX, MX, EY, MY, FCES | n | Pest control | 20:11 |
| 17:05 | EE | Fil | EX, EY | YES, n | Checking all racks | 19:56 |
| 17:26 | FAC | Eric, contractor | LVEA | n | Patching wall holes | 19:28 |
| 17:36 | PCAL | Francisco | PCAL Lab | y(local) | Grabbing stuff for PCAL meas | 17:52 |
| 17:45 | PEM | RyanC | EX, FCES | n | Checking dust monitors | 18:31 |
| 17:49 | PCAL | Francisco | EX | YES | PCAL measurements | 20:02 |
| 18:09 | FAC | Kim, Nelly | LVEA | n | Tech clean | 19:08 |
| 18:11 | TCS | Camilla | LVEA | n | Adjusting CO2 power | 18:22 |
| 18:30 | SEI | Jim | CR | n | Testing filters on BSCs | 20:26 |
| 18:34 | IAS | RyanC | LVEA | n | Setting up FARO for next week | 18:47 |
| 18:37 | TCS | Camilla | LVEA | n | CO2 laser work | 19:10 |
| 18:52 | PCAL | Rick, Mayank, Sivananda | EX | YES | Tour | 20:01 |
| 19:11 | HWS | TJ, Camilla | EY | n | Adding new collimator to HWS | 20:20 |
| 19:41 | VAC | Janos, JC | EY, MY, LVEA | YES | Fitting new exhaust filters for roughing pipes | 23:53 |
| 20:02 | PCAL | Francisco | PCAL Lab | y(local) | Dropping stuff off | 20:32 |
| 20:07 | PCAL | Rick, Sivananda, Mayank | PCAL Lab | y(local) | tour | 20:59 |
| 20:37 | EE | Fil | LVEA | n | Rack checks | 22:29 |
| 20:47 | SEI | Jim | CR | n | Tests on ETMX | 22:27 |
| 21:06 | OPS | Camilla | LVEA | YES | Transitioning LVEA to HAZARD | 21:27 |
| 21:27 | TCS | Camilla, TJ | LVEA | Y | HWS table work | 22:19 |
| 22:19 | OPS | Camilla | LVEA | Y -> N | SAFE transition | 22:26 |
| 22:46 | TCS | Camilla | LVEA | N | TCSY adjustment | 22:53 |
| 23:10 | EE | Daniel | LVEA | N | HAM1 investigation | 23:32 |