Reports until 17:12, Tuesday 14 January 2025
H1 CDS
david.barker@LIGO.ORG - posted 17:12, Tuesday 14 January 2025 - last comment - 10:43, Wednesday 15 January 2025(82282)
CDS Maintenance Summary: Tuesday 14th January 2025

WP12272 h1omc0 new RCG, quadratic filter ramping

Erik, Dave:

h1omc0 models were built against RCG 5.31 which introduces quadratic smoothing to ramped filter switching. All the models running on this frontend have the new rcg (h1iopomc0, h1omc, h1omcpi).

The overview was modified to show that h1omc0 has a different rgc than h1susex by colour coding the RCG: dark_blue=5.31(quadratic filter ramp and variable duotone frequence), light-blue-5.30 (LIGO DAC) and green = 5.14 (standard)

WP12274 h1guardian1 reboot

TJ, Erik:

TJ rebooted h1guardian1 to reload all the nodes. The hope is that this will eliminate the leap-second warnings we have been seeing on certain nodes.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 10:43, Wednesday 15 January 2025 (82295)

Tue14Jan2025
LOC TIME HOSTNAME     MODEL/REBOOT
08:06:21 h1omc0       h1iopomc0   <<< Install RCG5.31
08:06:35 h1omc0       h1omc       
08:06:49 h1omc0       h1omcpi     


17:30:10 h1omc0       h1iopomc0   <<< Revert back to RCG5.30
17:30:24 h1omc0       h1omc       
17:30:38 h1omc0       h1omcpi