Reports until 12:29, Wednesday 15 January 2025
H1 SUS
oli.patane@LIGO.ORG - posted 12:29, Wednesday 15 January 2025 (82296)
ALL* plotallsus_tfs.m scripts now plot cross-coupling

As an update to 80919, I have finished editing all*  plotallsus_tfs.m scripts to now include the plotting of cross-coupling. There is an on/off boolean along with a matrix near the top of each script that allows you to choose whether or not to plot cross coupling, and between which DOF.

This can help when we want to check for cross-coupling before vs after a period of time/vent/etc.

 

* When I say all I mean every sus matlab script whose name is a variation of plotallsus_tfs.m or plotallsus_tfs_M1.m. I did not update the plotallsus_spectra.m or plotallsus_tfs_{some other stage}.m since those are not used as often. All changes verified to work and committed to svn.