Displaying report 1-1 of 1.
Reports until 08:06, Wednesday 15 January 2025
H1 General (Lockloss)
anthony.sanchez@LIGO.ORG - posted 08:06, Wednesday 15 January 2025 - last comment - 13:36, Wednesday 15 January 2025(82287)
Wed Morning Shift

TITLE: 01/15 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 155Mpc
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 1mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.35 μm/s
QUICK SUMMARY:

When I walked in H1 had been locked and Observing for 33 minutes!

Unknown lockloss this morning at 13:17 UTC
H1 Manny relocked without assistance this morning and no one was even woken up.

 

PS: It's a little icey out in the parking lot so be prepared stepping out of your car.
 

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 13:36, Wednesday 15 January 2025 (82297)SUS

ETMY mode1s damping wasn't going well this morning and it was slowly rising (it did this a few times over the previous weekend as well), I went from +60 of phase to +30 and flipped the sign of the gain +0.1 -> -0.1, it has been damping for the past hour and has damped past where it was turning around with the previous settings.

Displaying report 1-1 of 1.