Reports until 09:13, Thursday 16 January 2025
H1 CAL
anthony.sanchez@LIGO.ORG - posted 09:13, Thursday 16 January 2025 (82305)
Calibration Sweep

Latest Calibration:
gpstime;python /ligo/groups/cal/src/simulines/simulines/simuLines.py -i /ligo/groups/cal/H1/simulines_settings/newDARM_20231221/settings_h1_newDARM_scaled_by_drivealign_20231221_factor_p1.ini;gpstime

notification: end of measurement
notification: end of test
diag> save /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250116T163130Z.xml
/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250116T163130Z.xml saved
diag> quit
EXIT KERNEL

2025-01-16 08:36:40,405 bb measurement complete.
2025-01-16 08:36:40,405 bb output: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250116T163130Z.xml
2025-01-16 08:36:40,405 all measurements complete.
 

 


gpstime;python /ligo/groups/cal/src/simulines/simulines/simuLines.py -i /ligo/groups/cal/H1/simulines_settings/newDARM_20231221/settings_h1_newDARM_scaled_by_drivealign_20231221_factor_p1.ini;gpstime
PST: 2025-01-16 08:40:33.517638 PST
UTC: 2025-01-16 16:40:33.517638 UTC
GPS: 1421080851.517638

2025-01-16 17:03:33,281 | INFO | 0 still running.
2025-01-16 17:03:33,281 | INFO | gathering data for a few more seconds
2025-01-16 17:03:39,283 | INFO | Finished gathering data. Data ends at 1421082236.0
2025-01-16 17:03:39,501 | INFO | It is SAFE TO RETURN TO OBSERVING now, whilst data is processed.
2025-01-16 17:03:39,501 | INFO | Commencing data processing.
025-01-16 17:03:39,501 | INFO | Ending lockloss monitor. This is either due to having completed the measurement, and this functionality being terminated; or because the whole process was aborted.
2025-01-16 17:04:16,833 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250116T164034Z.hdf5
2025-01-16 17:04:16,840 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250116T164034Z.hdf5
2025-01-16 17:04:16,845 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250116T164034Z.hdf5
2025-01-16 17:04:16,850 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250116T164034Z.hdf5
2025-01-16 17:04:16,854 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250116T164034Z.hdf5
ICE default IO error handler doing an exit(), pid = 1289567, errno = 32
PST: 2025-01-16 09:04:16.931501 PST
UTC: 2025-01-16 17:04:16.931501 UTC
GPS: 1421082274.931501

Images attached to this report