TITLE: 01/21 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Just got back into Observing after popping out to adjust the opo temperature. Our range had been steadily dropping over the past few locks and had gotten down below 150 Mpc, and our squeezing was getting worse along with it, so I decided to try adjusting the opo temperature before I left. I got us from an average of -3 down to -4.5dB squeezing for the 1.7kHz band. The evening has been quiet and relocking went well earlier with nothing needing to be touched.
LOG:
00:08 Lockloss
01:12 NOMINAL_LOW_NOISE
01:15 Observing
05:54 Out of Observing to adjust OPO temp
06:00 Back into Observing
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 23:16 | Corey | Optics lab | n | Looking for stuff | 00:13 |