david.barker@LIGO.ORG - posted 18:05, Wednesday 23 October 2013 (8240)
RCG2.8 testing completed, reverted back to RCG2.7.2

Rolf, Jim, Dave

After running at RCG2.8 for several hours we reverted the end station and ISC systems back to RCG2.7.2.

The 2.8 test was a success, we did not find any data errors transferring slow data directly to the data concentrator. CPU usage, network usages and frame sizes changed as expected.

During the make install-modelname process to reinstall 2.7.2, I accidentally recompiled the h1susauxex, h1iscex and h1susex models. There does not appear to be any local changes to these models, so the same code should be running on these systems. Jeff subsequently changed the quad models after we had reverted.