Displaying report 1-1 of 1.
Reports until 09:48, Friday 24 January 2025
H1 CAL
matthewrichard.todd@LIGO.ORG - posted 09:48, Friday 24 January 2025 (82440)
Calibration back to using new anti-aliasing filters in DCPD channels
[Evan Louis Matthew]

This morning after Evan and Louis fixed the anti-aliasing filters we used our 'lockloss-less' recipe to re-engage the filters while smoothly changing the demod phase. This required a slight adjustment to the arguments in the command LHO:82430 (listed below).

The new filters seem to be working as expected and are not causing yesterday's calibration error. This transition was done without lockloss.

This is a placeholder alog to state that the calibration and the ifo have been reverted to their nominal state from this morning. I'll follow up and edit this entry with additional details later tonight/ tomorrow morning.

To bring the filters back on and step the phase rot back to modified angle in same ramp time as the filters' ramps.
cdsutils switch H1:OMC-DCPD_A0 FM10 ON; cdsutils switch H1:OMC-DCPD_B0 FM10 ON; cdsutils step -s 0.065 H1:OMC-LSC_PHASEROT -- -1.0,77
Displaying report 1-1 of 1.