DQ shift report for 30 Dec 2024 - 5 Jan 2025
Summary of the report:
LHO was observing for an average of 85.8% of the time this week.
Some of the locklosses happened due to earthquakes, but for some, no apparent cause was known.
The average range stayed around 160 Mpc. But it dropped to ~140 Mpc for a brief period of time on Monday due to squeezer issues.
There were some high frequency (above 500 Hz) strain lines were present in the h(t) spectrogram some days of the week.
Nothing unusual in the glitches. Sometimes the glitchrates increased due to ground motion.
There were some low frequency (6-8 Hz) noises present in the BSCs during the later half of the week.
In both EX and EY accoustics, some (10-80 Hz) noises appeared consistently everyday.
Hveto: There were some new channels during the week (please see detailed report for the channel names).
Fscan: The line counts stayed around 700, but increased to 800 on Tuesday. But it never crossed the threshold.