J. Kissel, (with help from E. von Reis, D. Barker) ECR E2500017 IIET Ticket LHO:33143 WP 12302 I'm extending the infrastructure I installed July 2024 LHO:78956 in order to include replicas of the OMC DCPD GW channels' infrastructure further down the chain, namely to send the output of the 524 kHz test infrastructure over IPC to the 16 kHz OMC model to store the channels in the frames. This is result of the last two weeks' worth of use of the existing prototype infrastructure, and the findings that there may be some discrepancies between the offline down-sampled versions of the 524 kHz outputs and the 16 kHz online down-sampled versions (see LHO:82420) The simulink models touched for this update are /opt/rtcds/userapps/release/ cds/h1/models/h1iopomc0.mdl omc/h1/models/h1omc.mdl omc/common/models/omc.mdl In the attached collection of screenshots, I show "before" vs. "after" for these models, and the parts affected. (1) Top level of h1iopomc0 model before vs. after (2) Inside the OMC top_names block of the h1iopomc0 model before vs. after (3) Inside the OMC_DCPD block of the h1iopomc0.mdl model before vs. after (4) Top level of h1omc.mdl model before vs. after (5) Inside the OMCNEW block of the omc.mdl library which is used and renamed as just OMC in the h1omc.mdl model before vs. after (6) Inside the OMC_DCPD block of the OMCNEW block before vs. after I note in as a part of (6) I've re-organized the primary DCPD A and DCPD B SUM and NULL outputs such that it's much more legible than the previous version; again see that before vs. after More details to follow in the comments.
Because these models are run on the h1omc0 front-end, they all need to be compiled on the h11build machine with a special environment.
To create the special environment, after logging in as controls to the h1build machine, use the command to edit the following bash environment variables:
$ export RCG_SRC=/opt/rtcds/rtscore/advligorts-5.3.1_ramp
$ export RTS_VERSION=5.3.0~~dual_tone_frequency
Then you can do the standard
$ rtcds build h1iopomc0
... etc for each model.
Pending DAQ Changes for new models:
h1iopomc0:
h1omc: