Reports until 13:00, Monday 27 January 2025
H1 ISC
elenna.capote@LIGO.ORG - posted 13:00, Monday 27 January 2025 - last comment - 13:17, Monday 27 January 2025(82487)
Set POP A offsets

It was taking suspiciously long to converge the full IFO ASC at 2W, and Ryan and I saw that it was the PRM ADS that was taking forever to converge. This usually occurs because th POP A offsets are not set right so the PRM doesn't go to the right place in DRMI ASC.

I saw that the POP A offsets were OFF, probably left that way after this alog: 81849.

I set the offsets where we want them and turned them on. These settings are SDFed. This will improve locking time by a small amount.

Images attached to this report
Comments related to this report
ryan.short@LIGO.ORG - 13:17, Monday 27 January 2025 (82488)

Accepted in OBSERVE table.

Images attached to this comment