Displaying report 1-1 of 1.
Reports until 08:39, Thursday 30 January 2025
H1 General
corey.gray@LIGO.ORG - posted 08:39, Thursday 30 January 2025 - last comment - 11:23, Thursday 30 January 2025(82548)
ALSx Trigger Issues Again With No WFS

Similar to a few times yesterday, the X-arm's ALS_XARM guardian thought it was good with WFS OFFLOADED, but X-Arm's Auto Center is RED w/ no inputs to the WFS filter banks (similar to what I saw in June (alog 78326). 

I'm attaching screenshot which shows a little bit of everything with ALSx: 

Back in June, I clicked the FORCE button on the Trigger Window and this would bring Autocentering back.  (Right now I'm running an Initial Alignment and the Autocenter was still OFF....so I did another FORCE).

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 11:23, Thursday 30 January 2025 (82551)OpsInfo

Attached is an ndscope snapshot Ryan C. took from this morning where one can see the ITMx Camera is off in pitch and yaw and No WFS engaged for ALSx, but as soon as the Force button (H1:ALS-X_WFS_AUTOC_TRIG_FORCE) is pressed, ALSx WFS are engaged and aligment is optimized for the X-arm.  

Ryan  S. / Ryan C. also saw this ALSx beahvior over the weekend as well (alog 82464).

Images attached to this comment
Displaying report 1-1 of 1.