Reports until 18:27, Saturday 01 February 2025
H1 General (Lockloss)
ryan.short@LIGO.ORG - posted 18:27, Saturday 01 February 2025 - last comment - 20:01, Saturday 01 February 2025(82582)
Lockloss @ 02:03 UTC

Lockloss @ 02:03 UTC - link to lockloss tool

No obvious cause, but there's an ETMX glitch immediately prior. End lock stretch at 16.5 hours.

Images attached to this report
Comments related to this report
ryan.short@LIGO.ORG - 20:01, Saturday 01 February 2025 (82583)

H1 back to observing at 03:53 UTC.

I went immediately into an initial alignment to see if the ALS dropout issues were seen, and they were not. Since I believe this is the third time we've seen IA make the dropouts go away, is there something different about IA that fixes them?

Even with an alignment, relocking still took a while as there were ETMX saturations starting at DARM_TO_RF that eventually caused a lockloss during CARM_OFFSET_REDUCTION. Also, DRMI took a while to lock even with decent flashes.