OPS Wednesday day shift summary

TITLE: 02/05 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: 1 lockloss with an easy relock, we've been locked for 6 hours.
LOG:                                                                                                             

Start Time System Name Location Lazer_Haz Task Time End
17:16 SAFETY LASER SAFE  ( \u2022_\u2022) LVEA SAFE! LVEA  SAFE!!! 19:08
17:13 PSL Jason CR N ISS loop adjustment 17:15
17:15 CAL Tony PCAL lab Y PS11 measurement 17:40
18:03 FAC Kim Receiving N Cardboard 18:54
18:12 VAC Travis LVEA N Quick part check near high bay 18:16
19:31 FIT Matt Xarm N Runnin' 20:13
21:36 ISC Matt Optics lab N Cheeta optics mounting 22:28
21:40 CAL Tony PCAL lab Y PCAL work 22:28

17:10 UTC lockloss

18:34 UTC Observing

ITMY mode5/6s damping didn't seem to be going well today, I've been monitoring it on DTT after seeing the tall line on DARM and the DCPD min/max plot looking flat. I've found some new settings that seem to be bringing it down, based on the long & short monitors and DTT but more testing is needed to confirm. The new settings are FM5 + FM6 + FM10 G= -0.01, removing FM8. (Tagging SUS, OPS). I've set the gain to 0 in lscparams but I have not loaded the VIOLIN_DAMPING guardian.

21:52 UTC superevent S250205ee

00:00 - 00:03 UTC we dropped observing as the SUS_PI guardian fought (successfully) PI 24 in the new "XTREME_PI_DAMPING" state