Displaying report 1-1 of 1.
Reports until 17:29, Friday 07 February 2025
H1 SUS (SUS)
corey.gray@LIGO.ORG - posted 17:29, Friday 07 February 2025 (82692)
to do: VIOLIN_DAMPING needs a LOAD

See that h1's violin is still high, and then noticed that ITMy Mode5 is currently running with:  0.0 gain + FM8 ON.  To damp this down since the big ring-up on Tuesday, Ryan C found some settings which had been working (and after a few days of seeing them help, he updated lsc_params to with these new settings, BUT we need to run a LOAD of VIOLIN_DAMPING to implement these settings next time we are out of OBSERVING (this LOAD slipped my mind after my lockloss a few minutes before the end of my shift).

In the meantime, I made the change by hand (~13.5hrs into our current lock):

Displaying report 1-1 of 1.