Displaying report 1-1 of 1.
Reports until 13:12, Friday 25 October 2013
H1 SEI (SEI, SYS)
jeffrey.kissel@LIGO.ORG - posted 13:12, Friday 25 October 2013 (8270)
hepimaster.mdl, isi2stagemaster.mdl and isihammaster.mdl updated with 32bit parts
Fabrice, Stefan

Updated hepimaster.mdl, isi2stagemaster.mdl and isihammaster.mdl with the new 32-bit ODC libraries and routed the signals up to the top screen.
The are in svn as of revisions 6061 (isi's) and 6064 (hpimaster.mdl).

We modified the following 3 toplevel models, compiled and installed them:
h1hpiham4
h1isiitmy
h1isiham2
They all are running fine.

Fabrice is going to add more changes on the top level models before committing them to svn.




restart instructions
---------------------------------------

### recompile h1hpiham4
ssh h1build
cd /opt/rtcds/lho/h1/release

make h1hpiham4

### install h1hpiham4
make install-h1hpiham4

#log into the corresponding front end
ssh h1seih45
## shut down output on medm screen
starth1hpiham4 
# and hit BURT restore button
--------------------------------------------

## recompile and install h1isiitmy
ssh h1build
cd /opt/rtcds/lho/h1/release
make h1isiitmy
make install-h1isiitmy
ssh h1seib1
## shut down output on medm screen
starth1isiitmy 
# and hit BURT restore button
--------------------------------------------

## recompile and install h1isiham2
ssh h1build
cd /opt/rtcds/lho/h1/release
make h1isiham2     
make install-h1isiham2     
ssh h1seih23 
## shut down output on medm screen
starth1isiham2
# and hit BURT restore button


Displaying report 1-1 of 1.