Fabrice, Stefan Updated hepimaster.mdl, isi2stagemaster.mdl and isihammaster.mdl with the new 32-bit ODC libraries and routed the signals up to the top screen. The are in svn as of revisions 6061 (isi's) and 6064 (hpimaster.mdl). We modified the following 3 toplevel models, compiled and installed them: h1hpiham4 h1isiitmy h1isiham2 They all are running fine. Fabrice is going to add more changes on the top level models before committing them to svn. restart instructions --------------------------------------- ### recompile h1hpiham4 ssh h1build cd /opt/rtcds/lho/h1/release make h1hpiham4 ### install h1hpiham4 make install-h1hpiham4 #log into the corresponding front end ssh h1seih45 ## shut down output on medm screen starth1hpiham4 # and hit BURT restore button -------------------------------------------- ## recompile and install h1isiitmy ssh h1build cd /opt/rtcds/lho/h1/release make h1isiitmy make install-h1isiitmy ssh h1seib1 ## shut down output on medm screen starth1isiitmy # and hit BURT restore button -------------------------------------------- ## recompile and install h1isiham2 ssh h1build cd /opt/rtcds/lho/h1/release make h1isiham2 make install-h1isiham2 ssh h1seih23 ## shut down output on medm screen starth1isiham2 # and hit BURT restore button